Reports

Report identifiers, not customer names

Reports are issued under a run ID and held for 24 months. This index lists the identifiers and the failure class each campaign found, so a prospective customer can see the shape of the work without reading anyone else's data.

Run IDClassStress familiesFirst failureStatus
RK-24031Handheld sensor Thermal, drop, IP67 Seal creep at −20 °CIssued
RK-24058Field gateway Random vibration, thermal cycling Connector retention under 8 g rmsIssued
RK-24077Battery pack enclosure Shock, IP69K, IK10 Bracket fatigue after 12 pulsesIssued
RK-24102Outdoor camera Humidity, thermal, jet Lens heater duty-cycle driftIssued
RK-24108Ruggedised compute Thermal step-stress, vibration Rail sag −11% at +85 °CIn triage
RK-24119Industrial UPS Thermal cycling, shock Cap holder resonance at 340 HzIn run
RK-24124Wearable tracker Immersion, drop, IK08 Pending intakeScheduled
What is not here. Full reports contain the customer's design detail and are not published. A customer can request a redacted sample report under the same failure-first format, with the traces replaced by synthetic data of the same shape.
Format

Reading a report

  1. Page one: failure list

    Ordered by reproduction rate. Each entry names the channel, the stimulus phase, and whether the failure is deterministic or intermittent.

  2. Page two: margin table

    Applied level against first-failure level per stress family, with the residual margin expressed in the units that will actually ship.

  3. Appendix: traces and script

    CSV per channel, the bench script verbatim, and the fixture drawing. Everything needed to re-derive the numbers.

  4. Recommendation sheet

    Per failure: design change, screening step, or accepted risk with the basis stated. Cost ranked against effect.