Limits, not brochure numbers
The figures below are the limits we will actually run to with a mounted, instrumented unit. Bare-table ratings are higher and are not what a customer campaign is quoted against.
| Bench | Range | Payload | Notes |
|---|---|---|---|
| Vibration — electrodynamic | 5–2000 Hz, sine; random to 12 g rms | 40 kg mounted | Per-axis fixture; slip table for horizontal runs |
| Shock — half-sine | Up to 40 g / 11 ms | 25 kg mounted | Six directions; waveform captured per pulse |
| Thermal chamber A | −40 to +150 °C | 8 units, 0.6 m³ | Programmable ramp 3–10 °C/min |
| Thermal chamber B | −70 to +180 °C | 4 units, 0.3 m³ | Used for step-stress and cold-start work |
| Humidity | 10–98 %RH, +10 to +85 °C | 4 units | Condensing and non-condensing profiles |
| Drop tower | 0.3–1.8 m, guided | 30 kg | Orientation jig for corner and edge drops |
| Ingress — jet | IPX5 / IPX6 / IP69K | — | Rotating nozzle stand, calibrated flow |
| Ingress — immersion | IPX7 / IPX8, to 2 m | — | Pressure hold with leak-down observation |
| Impact | IK08 / IK10 | — | Pendulum, 5 J and 20 J strikers |
What we measure, and how it reaches you
- ThermocouplesType K, 12 channels per chamber run, 1 Hz
- AccelerometersTriaxial ICP, 20 kHz per axis on shock runs
- Rail probes4 differential channels, 100 kHz, ±30 V
- CurrentHall clamp per unit, 1 kHz, autoranging
- EnvironmentChamber setpoint, actual, and door state logged alongside unit data
- ExportOne CSV per channel plus a merged event timeline
/api/v1/telemetry. The
handshake and the error codes are documented on the
telemetry page. Access is per-campaign and revoked at
report issue.
Fixture work is part of the campaign
A result is only as good as the mounting that produced it. We design and machine the fixture for each unit shape, and the drawing goes into the report so a follow-up round can reuse the same mechanical boundary.
Per-axis mounting
Separate fixture per axis rather than a compromise bracket, so the transfer function stays flat through the band that matters.
Representative clamping
Clamped where it will be clamped in service. A unit bolted to a rigid plate passes tests it would fail in the field.
Retained geometry
Fixture drawings are archived with the run ID, so revision two is measured against revision one and not against a new fixture.